TM 9-2320-365-20-3
Change 2
13-30.1/(13-30.2 Blank)
(17) Position clamp (21) on return hose (25).
(18) Connect return hose (25) on power steering pump
reservoir (11).
(19) Engage as many clamp tabs (23) as possible in tab
windows (24) allowing little or no play between
clamp (21) and return hose (25).
(20) Tighten clamp (21) to 8-9 lb-in. (1 N
•m).
(21) Measure gap on clamp (21).
CAUTION
Clamp tongue must be started in clamp
groove.
Failure to comply may result in
damage to equipment.
NOTE
Minimum allowable gap on clamp is 0.2 in.
(5 mm).
If gap is less than 0.2 in. (5 mm),
remove and re-install clamp.