TM 9-2320-365-20-5
20-256.4
Change 2
20-48.
M1079 HEATER EMI SHIELDED FUEL PUMP REPLACEMENT (CONT)
(11) Remove four nuts (24), lockwashers (25), terminal
lug TL526 (26), four washers (27), screws (28), cable
assembly (29), and seal (30) from pump box (5).
Discard lockwashers and seal.
(12) Remove two nuts (31), seals (32), coupling (20), and
lockwasher (33) from pump box (5).
Discard seals and
lockwasher.