TM 9-2320-365-20-5
20-214
Change 2
20-41.
M1079 HEATER KIT INSTALLATION/REMOVAL (CONT)
(49) Remove 90-degree return fitting (93), 90-degree
fitting (86), and plug (96) from four-way fitting (94).
(50) Remove fitting (81) and plug (97) from run tee fitting
(98).
(51) Remove run tee fitting (98) from auxiliary supply port
(99).
(52) Apply sealing compound to threads of 90-degree
return fitting (93) and plug (100).
(53) Install 90-degree return fitting (93) on fuel tank
(95).
(54) Connect fuel hose (92) to 90-degree return fitting
(93).
(55) Install plug (100) in auxiliary supply port (99).
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing.
To avoid injury or death,
keep away from open fire and use in a
well-ventilated area. If adhesive, solvent,
or sealing compound gets on skin or
clothing, wash immediately with soap
and water.
Failure to comply may result
in injury to personnel.