6-2. 100 AMP ALTERNATOR REPAIR (CONT)
(28) Position fan (34) on shaft (3) with washer (35) and self-
locking nut (36).
(29) Tighten self-locking nut (36) to 50 lb-ft (68 N•m).
(30) Install cover (37) on front housing (7) with four
lockwashers (38) and screws (39).
(31) Install pulley bushing (40) and key (41) on shaft (3).
(32) Install washer (42) and self-locking nut (43) on shaft (3).
End of Task.