TM 9-2320-366-10-2
Table 3-2. Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
e. ELECTRICAL SYSTEM (CONT)
e30.
POWER TAKE-OFF (PTO) INDICATOR DOES NOT OPERATE (CONT).
(a)
Remove PDP cover (para 3-17a).
(b)
Shut down engine (para 2-27f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Engage PTO (para 2-65).
(e)
Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance.
(f)
Disengage PTO (para 2-65).
(g)
Install PDP cover (para 3-17b).
(h)
If PTO indicator still does not operate, notify Unit Maintenance.
e31.
FAN OFF INDICATOR DOES NOT OPERATE.
Check circuit breaker (CB22) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-17a).
(b)
Shut down engine (para 2-27f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Start engine (para 2-27a or b).
(e)
Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance.
(f)
Shut down engine (para 2-27f).
(g)
Install PDP cover (para 3-17b).
(h)
If fan off indicator still does not operate, notify Unit Maintenance.
e32.
DUMP BODY UP INDICATOR DOES NOT OPERATE.
Check circuit breaker (CB50) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-17a).
(b)
Lower dump body (para 2-38h).
(c)
Shut down engine (para 2-27f).
(d)
If circuit breaker is tripped, push in to reset.
(e)
Start engine (para 2-27a or b).
(f)
Raise dump body (para 2-38g).
3-48
Change 1