TM-9-2320-366-10-2

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; OPERATOR’S INSTRUCTIONS; VOLUME NO. 2 OF 2

AUGUST 2005
CHANGE 2

  TM-9-2320-366-10-2 - Page 579 of 930

TM 9-2320-366-10-2
Table 3-2. Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
e143.
TRANSMISSION AUXILIARY OIL COOLER FAN DOES NOT OPERATE (ALL MODELS
EXCEPT M1088/M1089).
Check circuit breaker (CB68) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-17a).
(b)
Position master power switch to off (para 2-27f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Position master power switch to on (para 2-27a or b).
(e)
Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance.
(f)
Position master power switch to off (para 2-27f).
(g)
Install PDP cover (para 3-17b).
(h)
If transmission auxiliary oil cooler fan still does not operate, notify Unit Maintenance.
e144.
M1088/M1089 TRANSMISSION AUXILIARY OIL COOLER FAN DOES NOT OPERATE.
Check circuit breaker (CB68) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-17a).
(b)
Position master power switch to off (para 2-27f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Position master power switch to on (para 2-27a or b).
(e)
Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance.
(f)
Position master power switch to off (para 2-27f).
(g)
Install PDP cover (para 3-17b).
(h)
If transmission auxiliary oil cooler fan still does not operate, notify Unit Maintenance.
e145.
M1088/M1089 WORKLIGHTS DO NOT ILLUMINATE.
Check circuit breaker (CB72) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-17a).
(b)
Position master power switch to off (para 2-27f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Position master power switch to on (para 2-27a or b).
Change 1
3-79


Back to Top