TM 9-2320-366-10-2
Table 3-2. Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
e93.
ENGINE FAN DOES NOT TURN OFF USING RADIATOR FAN OFF SWITCH (CONT).
(g)
Install PDP cover (para 3-17b).
(h)
If engine fan still does not turn off using radiator fan off switch, notify Unit Maintenance.
e94.
ETHER START DOES NOT OPERATE.
Check circuit breaker (CB22) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-17a).
(b)
Position master power switch to off (para 2-27f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Attempt to start engine (para 2-27a or b).
(e)
Position master power switch to off (para 2-27f).
(f)
Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance.
(g)
Install PDP cover (para 3-17b).
(h)
If ether start still does not operate, notify Unit Maintenance.
e95.
EXCESSIVE CONDENSATION IN FUEL.
Check circuit breaker (CB79) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-17a).
(b)
If circuit breaker is tripped, push in to reset. If circuit breaker is tripped or trips again, notify Unit
Maintenance.
(c)
Install PDP cover (para 3-17b).
(d)
If excessive condensation is still in fuel, notify Unit Maintenance.
e96.
RADIO DOES NOT OPERATE.
Check circuit breaker (CB20) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-17a).
(b)
Position radio to OFF.
(c)
Position master power switch to off (para 2-27f).
(d)
If circuit breaker is tripped, push in to reset.
(e)
Position master power switch to on (para 2-27a or b).
(f)
Position radio to on.
(g)
If circuit breaker is tripped or trips again, notify Unit Maintenance.
Change 1
3-71