TM 9-2320-366-10-2
Table 3-2. Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
e. ELECTRICAL SYSTEM (CONT)
e69.
INTERVEHICLE RIGHT TURN SIGNAL DOES NOT OPERATE.
Notify Unit Maintenance.
e70.
INTERVEHICLE STOPLIGHTS DO NOT OPERATE.
Notify Unit Maintenance.
e71.
INTERVEHICLE TAILLIGHTS DO NOT OPERATE.
Notify Unit Maintenance.
e72.
PERSONNEL HEATER CONTROL ILLUMINATION DOES NOT OPERATE.
Step 1. Check operation of all vehicle lights (para 2-27c).
If either light is not working, notify Unit Maintenance.
Step 2. Check circuit breaker (CB23) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-17a).
(b)
Position main light switch to OFF (para 2-27c).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Position main light switch to SER DRIVE (para 2-27c).
(e)
Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance.
(f)
Position main light switch to OFF (para 2-27c).
(g)
Install PDP cover (para 3-17b).
(h)
If personnel heater control illumination still does not operate, notify Unit Maintenance.
e73.
PERSONNEL HEATER FAN DOES NOT OPERATE.
Check circuit breaker (CB23) in PDP to see if it is tripped.
(a)
Remove PDP cover (para 3-17a).
(b)
Position master power switch to off (para 2-27f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Position master power switch to on (para 2-27a or b).
(e)
Check circuit breaker in PDP to see if it is tripped. If circuit breaker is tripped, notify Unit
Maintenance.
(f)
Position master power switch to off (para 2-27f).
(g)
Install PDP cover (para 3-17b).
(h)
If personnel heater fan still does not operate, notify Unit Maintenance.
3-62