Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes.
Failure to comply
may result in damage to equipment.
CAUTION
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability.
Check that
connector pins are not pushed back and
are capable of making good contact.
TM 9-2320-366-20-1
Change 1
2-322.1
(1)
Connect connector PX9 to fuel gage
connector.
(2)
Connect connector clamp on fuel gage
connector.
(3)
Install instrument panel assembly
(para 7-15).
(4)
Set multimeter to ohms.
(5)
Connect positive (+) probe of multimeter
to connector P82 socket 2.
(6)
Connect negative (-) probe of multimeter
to a known good ground and note
reading on multimeter.
(7)
If continuity is not present, repair wire
3001 from connector P82 socket 2 to
terminal lug TL83 (para 2-45) or replace
start and charging cable assembly
(para 7-132).
(8)
If continuity is present, replace fuel level
sensor (para 4-8).
(9)
Connect connector P82 to fuel level
sensor.
(10)
Connect connector clamp on fuel level
sensor.
CONTINUITY TEST