TM-9-2320-366-20-2

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 2 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-2 - Page 105 of 1632

TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
2-991
2-991
2-991
2-991
2-991
CONTINUITY TEST
(1)
Remove six screws from auxiliary panel.
(2)
Lift auxiliary panel from auxiliary panel
housing to gain access.
(3)
Disconnect connector P903 from WINCH
IN/OUT switch.
(4)
Set multimeter to ohms.
(5)
Connect positive (+) probe of multimeter to
WINCH IN/OUT switch terminal 3.
(6)
Connect negative (-) probe of multimeter to
WINCH IN/OUT switch terminal 1.
(7)
Position WINCH IN/OUT switch to in
(TM 9-2320-366-10-1) and note reading on
multimeter.
(8)
If continuity is not present, replace
WINCH IN/OUT switch (para 7-18).


Back to Top