NO
YES
YES
3.
Notify DS Maintenance.
Notify DS Maintenance.
Battery voltage OK.
Input voltage to overload
shutdown system OK.
Hydraulic system shutdown
solenoid OK.
Hydraulic system shutdown
relay OK.
Crane functions OK.
Overload lockout cable OK.
Overload shutdown box OK.
Tension load cell OK.
Proximity sensor OK.
Telescope out lockout
solenoid cable OK.
Faulty solenoid valve
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
Continuity Test or
STE/ICE-R #91
REASON FOR QUESTION
Telescope out lockout will
not operate if continuity is
not present across telescope
out lockout solenoid valve
contacts.
Is continuity present across
telescope out lockout
solenoid valve contacts?
e119.