VOLTAGE TEST
Remove rings, bracelets, watches, necklaces,
and any other jewelry before working around
vehicle. Jewelry can catch on equipment and
cause injury or short across electrical circuit
and cause severe burns or electrical shock.
WARNING
VOLTAGE TEST
(1)
Set multimeter to vdc.
(2)
Connect positive (+) probe of multimeter to
D6 of junction box.
(3)
Connect negative (-) probe of multimeter to
GROUND quick-connect terminal block (above
main power switch) and note reading on
multimeter.
(4)
If 24 vdc is not present, repair junction box
assembly (para 7-28).
(1)
Set multimeter to vdc.
(2)
Connect positive (+) probe of multimeter to
D7 of junction box.
(3)
Connect negative (-) probe of multimeter to
GROUND quick-connect terminal block (above
main power switch) and note reading on
multimeter.
(4)
If 24 vdc is not present, repair junction box
assembly (para 7-28).