TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
2-1292
2-1292
2-1292
2-1292
2-1292
YES
START
1.
NO
WARNING
Read WARNING
on following page.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
Battery voltage OK.
Circuit breakers OK.
Power control cable
assembly OK.
Auxiliary panel cable
assembly OK.
Dashboard cable
assembly OK.
Hydraulic system OK.
Faulty crane power cable.
Faulty junction box
assembly.
Is 24 vdc present at
junction box assembly
terminal board position 2?
INITIAL SETUP
Equipment Conditions
Engine shut down (TM 9-2320-366-10-1).
Personnel Required
(2)
Tools and Special Tools
Tool Kit, Genl Mech (Item 46, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
STE/ICE-R (Item 41, Appendix C)
References
TM 9-491-571-12&P
Voltage Test or
STE/ICE-R Test #89
REASON FOR QUESTION
If 24 vdc is not present,
crane power cable is
faulty.
e120.
M1089 MATERIAL HANDLING CRANE (MHC) DOES NOT OPERATE
Replace crane power
cable (para 7-79).