NO
YES
KNOWN INFO
TEST OPTIONS
REASON FOR QUESTION
2.
WARNING
Read WARNING
on following page.
Battery voltage OK.
Overload shutdown
system OK.
Hydraulic system
shutdown relay OK.
Remote control cables OK.
POSSIBLE PROBLEMS
Faulty external remote
control cable.
Faulty crane remote
control box.
Is 24 vdc present at
pin E of external remote
control cable connector?
Voltage Test or
STE/ICE Test #89
If 24 vdc is not present,
external remote control
cable is faulty.
Replace external remote
control cable.