TM-9-2320-366-20-2

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 2 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-2 - Page 431 of 1632

TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
2-1307
2-1307
2-1307
2-1307
2-1307
OUTPUT VOLTAGE TEST
Remove rings, bracelets, watches, necklaces,
and any other jewelry beffore working around
vehicle. Jewelery can catch on equipment and
cause injury or short circuit across electrical
circuits and cause severe burns or electrical
shock.
WARNING
(9)
Position HOIST UP/DOWN controller to UP and
note reading on multimeter.
(10)
If 24 volts dc is not present, go to step 3 of
this fault.
(11)
Position MAIN POWER switch to OFF.
NOTE
Step (9) requires the aid
of an assistant.
(1)
Connect external remote control cable to and
remote control box (TM 9-2320-366-10-1).
(2)
Loosen four screws on junction box.
(3)
Open cover on junction box.
(4)
Position MAIN POWER switch to ON.
(5)
Lift guard and position remote control box
ON/OFF switch to ON.
(6)
Set multimeter to volts dc.
(7)
Connect positive (+) probe of multimeter on
terminal board lower position 15.
(8)
Connect negative (-) probe of multimeter on
ground quick-connect terminal board
(above MAIN POWER switch).


Back to Top