2.
YES
Other crane functions from
remote station OK.
Remote control box OK.
HOIST UP/DOWN
controller OK.
Faulty hoist up solenoid
cable.
Faulty hoist up solenoid.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
Continuity Test or
STE/ICE Test #91
REASON FOR QUESTION
If continuity is not present,
hoist up solenoid cable is
faulty. If continuity is
present, hoist up solenoid
is faulty.
Notify DS Maintenance.
Is continuity present
from hoist up solenoid
cable connector pin 2
to ground and from
pin 1 to terminal board
lower position 15?
NO
Replace hoist up solenoid
cable (para 7-113).