Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes.
Failure to comply
may result in damage to equipment.
CAUTION
NOTE
CONTINUITY TEST
Inspect connector pins/sockets for damage,
corrosion, and serviceability.
Check that
connector pins are not pushed back and
are capable of making good contact.
TM 9-2320-366-20-2
Change 1
2-1450.25
(1) Disconnect batteries (para 7-57).
(2) Remove kick panel (para 16-3).
(3) Disconnect connector J108 from connector
P108.
(4) Remove circuit breaker CB50 from PDP.
(5) Set multimeter to ohms.
(6) Connect positive (+) probe of multimeter
to connector J108 pin 16.
(7) Connect negative (-) probe of multimeter to
circuit breaker CB50 socket 2 and note
reading on multimeter.
(8) If continuity is not present, go to step 17 of
this fault.