Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes.
Failure to comply
may result in damage to equipment.
CAUTION
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability.
Check that
connector pins are not pushed back and
are capable of making good contact.
TM 9-2320-366-20-2
Change 1
2-1451
CONTINUITY TEST
(1) Remove personnel heater for access
(para 18-9).
(2) Disconnect connector P912 from connector
J912.
(3) Set multimeter to ohms.
(4) Connect positive (+) probe of multimeter
to connector J108 pin 16.
(5) Connect negative (-) probe of multimeter to
connector J912 pin/socket 1 and note
reading on multimeter.
(6) If continuity is not present, repair wire
2006 from connector J108 pin 16 to
connector J912 socket 1 (para 2-45) or
replace auxiliary panel cable assembly
(para 7-58).
(7) If continuity is present, repair wire 2006
from circuit breaker CB50 socket 2 to
connector P912 pin 1 (para 2-45) or
replace WTEC II dashboard cable assembly
(para 7-10) or WTEC III dashboard cable
assembly (para 7-11).
(8) Connect connector P912 to connector
J912.
(9) Install personnel heater (para 18-9).
(10) Connect connector J108 to connector
P108.
(11) Install circuit breaker CB50 in PDP.
(12) Install kick panel (para 16-3).
(13) Install wrecker control panel top cover
(para 14-4).
(14) Connect batteries (para 7-57).