TEST OPTIONS
REASON FOR QUESTION
KNOWN INFO
NO
YES
2.
TM 9-2320-366-20-2
e148. M1088/M1089 WORKLIGHTS DO NOT ILLUMINATE (CONT)
2-1542
Change 1
Continuity Test or
STE/ICE-R Test #91
POSSIBLE PROBLEMS
Circuit breakers CB71, CB72,
and CB74 OK.
Hazard lights illuminate.
Light bulb OK.
Auxiliary panel cable
assembly OK.
Relay K9 OK.
Diode D2B OK.
Faulty worklights switch.
Faulty dashboard cable
assembly.
Faulty relay K12.
If continuity is not present,
worklights switch is faulty.
Is continuity present from
worklight switch terminal
1 to terminal 5?
Replace worklights
switch (para 7-18).