TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
2-1576
2-1576
2-1576
2-1576
2-1576
1.
START
One crane worklight
illuminates.
If 12 vdc is not present,
wire 2004 is faulty.
YES
NO
KNOWN INFO
POSSIBLE PROBLEMS
Faulty crane worklight.
Faulty crane power cable
assembly.
WARNING
Read WARNING
on following page.
Is 12 vdc present at
connector P136-B
(RH worklight) or
connector P135-B
(LH worklight)?
TEST OPTIONS
Voltage Test or
STE/ICE-R #89
REASON FOR QUESTION
Tools and Special Tools
Tool Kit, Genl Mech (Item 46, Appendix C)
STE/ICE-R (Item 41, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
References
TM 9-4910-571-12&P
e152.
M1084/M1086 WORKLIGHTS DO NOT ILLUMINATE
INITIAL SETUP
Equipment Condition
Engine shut down (TM 9-2320-366-10-1).
Personnel Required
(2)
Materials/Parts
Wire, Elect, 50 ft (Item 71, Appendix D)
Repair wire 2004 (para 2-45)
or replace crane power
cable assembly (para 7-79).