TM 9-2320-366-20-3
TM 9-2320-366-20-3
TM 9-2320-366-20-3
TM 9-2320-366-20-3
TM 9-2320-366-20-3
2-2387
2-2387
2-2387
2-2387
2-2387
CONTINUITY TEST
CONTINUITY TEST
(1)
Open cover on LMHC control box.
(2)
Set multimeter to ohms.
(3)
Connect positive (+) probe of multimeter to
NATO plug positive (+) terminal.
(4)
Connect negative (-) probe of multimeter to
LMHC control box circuit breaker supply post
and note reading on multimeter.
(5)
If continuity is not present, replace wire 170
(para 20-70).
(1)
Disconnect LMHC control box power cable
from LMHC control box connector.
(2)
Set multimeter to ohms.
(3)
Connect positive (+) probe of multimeter to
NATO plug negative (-) terminal.
(4)
Connect negative (-) probe of multimeter to
LMHC control box connector pin B and note
reading on multimeter.
(5)
If continuity is not present, replace wire 150
(para 20-70).
(6)
Install cover and retainer on NATO plug with
eight screws.