TM 9-2320-366-20-3
TM 9-2320-366-20-3
TM 9-2320-366-20-3
TM 9-2320-366-20-3
TM 9-2320-366-20-3
2-2391
2-2391
2-2391
2-2391
2-2391
CONTINUITY TEST
(1)
Disconnect LMHC control power cable from
LMHC winch assembly power connector.
(2)
Set multimeter to ohms.
(3)
Connect positive (+) probe of multimeter to
one end of LMHC control box power cable
socket A.
(4)
Connect negative (-) probe of multimeter to
other end of LMHC control box power cable
socket A and note reading on multimeter.
(5)
If continuity is not present, replace LMHC
control box power cable.
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
LMHC control box power cable socket B.
(
3
)
Connect negative (-) probe of multimeter to
LMHC control box power cable socket B and
note reading on multimeter.
(
4
) If continuity is not present, replace LMHC
control box power cable.
CONTINUITY TEST