TM-9-2320-366-20-3

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 3 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-3 - Page 458 of 1396

KNOWN INFO
WARNING
Read WARNING
on following page.
YES
NO
TEST OPTIONS
REASON FOR QUESTION
Air Pressure Test
STE/ICE-R Test #50
2.
Replace air hose (para 23-5).
Notify DS Maintenance, LH 30K
winch assembly is faulty.
If 75-120 PSI (518-827 kPa) is
not present, air hose is faulty.
If 75-120 PSI (518-827 kPa) is
present, LH 30K winch
assembly is faulty.
aa2. MAIN WINCH LH FREESPOOL DOES NOT OPERATE (CONT)
POSSIBLE PROBLEMS
Faulty air hose.
Faulty LH 30K winch
assembly.
Is 75-120 PSI
(518-837 kPa) present at LH
30K winch freespool input
90 degree fitting?
TM 9-2320-366-20-3
2-2424
Change 1
LH 30K winch operates.
STATION SELECTOR switch to
WRECKER CONTROL PANEL.
MODE SELECTOR SWITCH to
NORMAL.
MAIN WINCH LH SPEED
switch operates.
RH 30K winch freespools.
MAIN WINCH LH FREESPOOL
switch OK.
M1089 control panel wiring
harness OK.
Terminal block jumper OK.
30K winch pneumatic manifold
solenoid L19 OK.


Back to Top