KNOWN INFO
WARNING
Read WARNING
on following page.
YES
NO
TEST OPTIONS
Air Pressure Test
STE/ICE-R Test #50
POSSIBLE PROBLEMS
1.
REASON FOR QUESTION
START
Is 75-120 PSI
(518-837 kPa) present at
input tee fitting on pressure
regulator valve?
Go to step 5 of this fault.
This question eliminates
possible problems and
determines where
troubleshooting continues.
Faulty pressure protection
valve.
Faulty air hose.
Faulty M1089 30K winch
manifold assembly.
Faulty M1089 30K winch
pneumatic manifold assembly.
NOTE
aa4. MAIN WINCH LH AND RH FREESPOOLS DO NOT OPERATE
Tools and Special Tools
Tool Kit, Genl Mech (Item 46, Appendix C)
STE/ICE-R (Item 41, Appendix C)
M1089 30K Winch Pneumatic Test Adapter
(Item 25, Appendix E)
M1089 30K Winch Test Adapter
(Item 7, Appendix E)
Goggles, Industrial (Item 15, Appendix C)
Material/Parts
Tape, Antiseizing (Item 66, Appendix D)
Perform Electrical System Troubleshooting task
e140.
Main Winch LH or RH Freespool Switch
Does Not Operate prior to beginning
this task.
TM 9-2320-366-20-3
2-2428
Change 1
LH and RH 30K winches
operates.
STATION SELECTOR switch to
WRECKER CONTROL PANEL.
MODE SELECTOR SWITCH to
NORMAL.
MAIN WINCH LH and RH
SPEED switch operates.
Terminal block jumper OK.
INITIAL SETUP
Equipment Conditions
Engine shut down (TM 9-2320- 366-10-1).
Air tanks drained (TM 9-2320-366-10-1).
Personnel Required
(2)
References
TM 9-4910-571-12&P