TM-9-2320-366-20-3

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 3 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-3 - Page 472 of 1396

KNOWN INFO
WARNING
Read WARNING
on following page.
YES
NO
TEST OPTIONS
REASON FOR QUESTION
Air Pressure Test
STE/ICE-R Test #50
POSSIBLE PROBLEMS
Faulty pressure protection
valve.
Faulty air hose.
5.
Is 75-120 PSI
(518-827 kPa) present at
90 degree fitting of pressure
protection valve?
If 75-120 PSI (518-827 kPa) is
not present, pressure
protection valve is faulty.
If
75-120 PSI (518-827 kPa) is
present, air hose is faulty.
Replace air hose (para 23-5).
Replace pressure protection
valve (para 11-29).
aa4.
MAIN WINCH LH AND RH FREESPOOLS DO NOT OPERATE (CONT)
TM 9-2320-366-20-3
2-2428.8
Change 1
LH and RH 30K winches
operates.
STATION SELECTOR switch to
WRECKER CONTROL PANEL.
MODE SELECTOR SWITCH to
NORMAL.
MAIN WINCH LH and RH
SPEED switch operates.
Terminal block jumper OK.