KNOWN INFO
1.
NO
Go to step 3 of this fault.
YES
TEST OPTIONS
Air Pressure Test
STE/ICE-R Test #50
REASON FOR QUESTION
This question eliminates
possible problems and
determines where
troubleshooting continues.
aa5.
M1089 LH OR RH 30K WINCH CABLE DRUM TENSIONER DOES NOT OPERATE
POSSIBLE PROBLEMS
Is 55-65 PSI (380-448 kPa)
present at output 90 degree
fitting of shuttle valve?
WARNING
Read WARNING
on following page.
NOTE
M1089 LH and RH 30K winch cable drum
tensioners are tested the same way.
LH
side shown.
INITIAL SETUP
Equipment Conditions
Engine shut down (TM 9-2320-366-10-1).
Air tanks drained (TM 9-2320-366-10-1).
M1089 control panel covers removed (para 17-20)
(RH side).
Personnel Required
(2)
References
TM 9-4910-571-12&P
Tools and Special Tools
Tool Kit, Genl Mech (Item 46, Appendix C)
STE/ICE-R (Item 41, Appendix C)
M1089 30K Winch Pneumatic Test Adapter
(Item 25, Appendix E)
Goggles, Industrial (Item 15, Appendix C)
Nut, Self-Locking (2) (Item 133, Appendix G)
Sealing Compound (Item 58, Appendix D)
Main winch LH/RH freespools.
Faulty M1089 LH/RH 30K
winch cable tensioner.
Faulty 30K winch pneumatic
manifold solenoid L8/L4.
Faulty M1089 LH/RH 30K
winch pneumatic valve
assembly.
Faulty air hose.
2-2430
Change 1
TM 9-2320-366-20-3