TM-9-2320-366-20-3

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 3 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-3 - Page 483 of 1396

AIR PRESSURE TEST
NOTE
(12)
Shut down engine (TM 9-2320-366-10-1).
(13)
Drain air tanks (TM 9-2320-366-10-1).
(14)
Disconnect input air hose from output 90
degree fitting of regulator valve.
(15)
Remove STE/ICE-R 0-1000 PSI transducer
from output port of regulator valve.
(16)
Close LH and RH catwalks.
NOTE
Perform step (17) for M1089 RH 30K
winch cable drum tensioner.
AIR PRESSURE TEST (Cont)
TM 9-2320-366-20-3
Change 1
2-2431
(26)
Remove STE/ICE-R 0-1000 PSI transducer
from output port of regulator valve.
(27)
Apply sealing compuond to threads of pipe
nipple.
(28)
Install regulating valve on pipe nipple.
(29)
Install 30K winch tension Pneumatic
valve assembly (para 17-30).
(30)
Close LH and RH catwalks.
(17)
Install M1089 control panel covers
(para 17-20).
(18)
Pull out and turn knob on regulator valve
fully counter clockwise.
(19)
Pull out and turn knob on regulator valve
clockwise until STE/ICE-R shows between
55-65 PSI (380-440 kPa).
(20)
If 55-65 PSI (380-440 kPa) is present after
adjustment, perform steps (23) through (30).
(21)
If 55-65 PSI (380-440 kPa) is still not present
after adjustment, replace regulator valve
(para 17-30).
(22)
Perform steps (12) through (17).
(23)
Shut down engine (TM 9-2320-366-10-1).
(24)
Drain air tanks (TM 9-2320-366-10-1).
(25)
Disconnect input air hose from input 90
degree fitting of regulator valve.
(1)
Disconnect air hose from adapter fitting on
shuttle valve.
(2)
Disconnect air hose from 90 degree fitting
on shuttle valve.
(3)
Remove two self-locking nuts, washers,
screws, and shuttle valve from bulkhead.
Discard self-locking nuts.
(4)
Position shuttle valve in vise.
(5)
Remove regulator valve from pipe nipple.
(6)
Install STE/ICE-R 0-1000 PSI pressure
transducer in output port of regulator valve.
(7)
Connect input air hose to input 90 degree
fitting of regulator valve.
(8)
Start engine (TM 9-2320-366-10-1) and
allow vehicle to build air pressure.
(9)
Perform STE/ICE-R Test #50 and note
reading on STE/ICE-R.
(10)
If 55-65 PSI (380-440 kPa) is not present,
perform step (18) through (22).
(11)
If 55-65 PSI (380-440 kPa) is present,
replace shuttle valve (para 17-30).
Tag air hoses and connection points prior
to disconnecting.


Back to Top