aa5.
M1089 LH OR RH 30K WINCH CABLE DRUM TENSIONER DOES NOT OPERATE (CONT)
KNOWN INFO
TEST OPTIONS
Air Pressure Test
STE/ICE-R Test #50
REASON FOR QUESTION
POSSIBLE PROBLEMS
Faulty 30K winch pneumatic
manifold solenoid L8/L4.
Faulty M1089 LH/RH 30K
winch pneumatic valve
assembly.
Faulty air hose.
YES
NO
3.
WARNING
Read WARNING
on following page.
Main winch LH/RH freespools.
2-2430.4
Change 1
TM 9-2320-366-20-3
Is 75-120 PSI
(518-827 kPa) present at
pneumatic manifold (refer to
Table 2-65.2.
30K Winch
Pneumatic Manifold Drum
Tensioner Solenoids) port 1?
Repair M1089 30K winch pneumatic
manifold solenoid or replace solenoid (refer to
Table 2-65.2.
30K Winch Pneumatic Manifold
Drum Tensioner Solenoids) (para 17-29).
If 75-120 PSI (518-827 kPa) is
not present, 30K winch
pneumatic manifold solenoid
L8/L4 is faulty.