NOTE
WARNING
Wear protective goggles to protect against
possible injury from release of high pressure
air.
Failure to comply may result in injury to
personnel.
AIR PRESSURE TEST STE/ICE-R TEST #50
(1) Remove wrecker control panel top cover
(para 14-4).
(2) Disconnect air hose from input fitting of
30K winch manifold assembly.
(3) Connect air hose to M1089 30K winch
pneumatic test adapter.
(4) Install STE/ICE-R 0-1000 PSI transducer in
M1089 30K winch pneumatic test adapter.
(5) Start engine (TM9-2320-366-10-1) and
allow vehicle to build air pressure.
(6) Perform STE/ICE-R Test #50 and note
reading on STE/ICE-R.
(7) If 75-120 PSI (518-827 kPa) is not present,
replace air hose (para 23-5).
(8) Shut down engine (TM 902320-366-10-1).
(9) Drain air tanks (TM9-2320-366-10-1).
(10) Remove STE/ICE-R 0-1000 PSI transducer
from M1089 30K winch pneumatic test
adapter.
(11) Disconnect air hose from M1089 30K
winch pneumatic test adapter.
TM 9-2320-366-20-3
Change 1
2-2428.5
Tag air hose and connection point prior to
disconnecting