TM 9-2320-366-20-5
Change 2
19-95
19-19.
HYDRAULIC RESERVOIR AND BRACKET REPLACEMENT (CONT)
(14) Apply sealing compound to threads of nut (20).
(15) Position nut (20) on strap (12).
(16) Tighten nut (20) to 42-52 ft-lb (57-71 N•m).
(17) Connect hose (21) to fitting (19).
(18) Connect hose (22) to 90-degree fitting (16).
(19) Position guard support bracket (23) on bracket (1)
with two bolts (24) and self-locking nuts (25).
(20) Position two bolts (24) and self locking nuts (25) in
guard support bracket (23) and stone guard (26).
(21) Tighten four self-locking nuts (25) to 20-24 lb-ft (27-
33 N•m).
e. Follow-On Maintenance.
(1)
Install hydraulic oil filter assembly (para 19-13).
(2)
Fill hydraulic reservoir (Appendix H).
End of Task.
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing.
Keep away from open fire
and use in a well-ventilated area.
If
adhesive, solvent, or sealing compound
gets
on
skin
or
clothing,
washer
immediately with soap and water.
Failure
to comply may result in injury to
personnel.
NOTE
Perform steps (19) through (21) on models
M1090 and M1094.