TM 9-2320-366-20-5
19-120
Change 2
19-22.
M1090/M1094 FOUR-WAY RELIEF VALVE SOLENOID REPLACEMENT (CONT)
(6)
Position drain pan under four-way relief valve (4).
(7)
Remove four screws (7) and solenoid valve (8)
from four-way relief valve (4).
(8)
Remove four preformed packings (9) from four-
way relief valve (4).
Discard preformed packings.
b. Installation.
(1)
Install four preformed packings (1) on four-way relief
valve (2).
(2)
Position solenoid valve (3) on four-way relief valve
(2)
with four screws (4).
(3)
Tighten four screws (4) to 45-55 lb-in. (5-6 N
m).
(4)
Install gasket (5) on connector L9 (6).
(5)
Connect connector L9 (6) to four-way relief valve
(2).