TM 9-2320-366-20-5
20-43. 200 AMP ALTERNATOR KIT INSTALLATION
This task covers:
a. Installation
b. Follow-On Maintenance
INITIAL SETUP
Equipment Conditions
100 amp alternator removed (para 7-2).
100 amp reverse polarity relay removed (para 7-30).
Tools and Special Tools
Tool Kit, Genl Mech (Item 46, Appendix C)
Wrench, Torque, 0-175 lb-ft (Item 58, Appendix C)
Wrench, Torque, 0-200 lb-in. (Item 59, Appendix C)
Socket Set, Socket Wrench (Item 36, Appendix C)
Caps, Vise Jaw (Item 4, Appendix C)
Vise, Machinist (Item 48, Appendix C)
Materials/Parts
Ties, Cable, Plastic (Item 69, Appendix D)
Nut, Self-Locking (Item 153, Appendix G)
Nut, Self-Locking (M1093/M1094) (2) (Item
156, Appendix G)
Nut, Self-Locking (3) (Item 168, Appendix G)
Washer, Spring (M1093/M1094) (2) (Item 293,
Appendix G)
Lockwasher (2) (Item 92, Appendix G)
Personnel Required
(2)
a. Installation.
NOTE
Retain
belt
adjusting
arm
for
future
installation.
(1) Remove two screws (1), lockwashers (2), and belt
adjusting arm (3) from alternator bracket (4). Discard
lockwashers.
(2) Position belt adjusting arm (5) on alternator bracket (4)
with two lockwashers (2) and screws (1).
(3) Tighten two screws (1) to 25-32 lb-ft (35-43 N·m).
Change 1
20-227