1.
NO
Clean or replace counterbalance
valve (para 17-3).
k3.
DUMP BODY DRIFTS DOWN FROM RAISED POSITION
Visual Inspection
REASON FOR QUESTION
2-1072.12
Change 2
Dump body raises and lowers
OK.
POSSIBLE PROBLEMS
Faulty counterbalance valve.
Faulty dump body hoist
cylinder.
Is counterbalance valve
free of debris and has no
damage to preformed
packings or back up rings?
Dump body may creep down
from raised position if counter-
balance valve is contaminated
and if preformed packings or
back-up rings are damaged.
INITIAL SETUP
Equipment Conditions
Engine shut down (TM 9-2320-366-10-1).
Tools and Special Tools
Tool Kit, Genl Mech (Item 78, Appendix B)
Pan, Drain (Item 42, Appendix B)
Gloves, Mens (Item 40.1, Appendix C)
Materials/Parts
Rag, Wiping (Item 60, Appendix C)
Personnel Required
(2)