Change 1
2-207
TM 9-2320-366-34-1
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
internal wiring harness 24-pin connector
pin A2.
(3)
Connect negative (-) probe of multimeter
to internal wiring harness connector A
pin B and note reading on multimeter.
(4)
If continuity is not present, replace
transmission internal wiring harness
(para 7-13).
(5)
Connect positive (+) probe of multimeter
to internal wiring harness 24-pin connector
pin A2.
(6)
Connect negative (-) probe of multimeter
to all other pins in internal wiring harness
24-pin connector, except D1 and H1, and
note reading on multimeter.
(7)
Connect negative (-) probe of multimeter
to ground and note reading on multimeter.
(8)
If continuity is present, transmission internal
wiring harness is shorted; replace
transmission internal wiring harness
(para 7-13).