TM-9-2320-366-34-2

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE; VOLUME NO. 2 OF 4

AUGUST 2005
CHANGE 2

  TM-9-2320-366-34-2 - Page 315 of 1434

TM 9-2320-366-34-2
(53) Position strap (57) on starting motor solenoid terminal
(58) and field coil screw (4).
WARNING
Adhesives,
solvents,
and
sealing
compounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area.
If
adhesive, solvent, or sealing compound
gets
on
skin
or
clothing,
wash
immediately with soap and water. Failure
to
comply
may
result
in
injury
to
personnel.
(54) Apply sealing compound to threads of starting motor
solenoid terminal (58) and field coil screw (4).
(55) Position nut (59) on field coil screw (4).
(56) Tighten nut (59) to 18-22 lb-ft (24-30 N·m).
(57) Position nut (60) on starting motor solenoid terminal (58).
(58) Tighten nut (60) to 21-29 lb-ft (28-39 N·m).
(59) Position preformed packing (61), isolator (62), two
washers (63), spring washers (64), nut (65), electrical
lead (66), and nut (65) on contact screw (19).
(60) Tighten two nuts (65) to 33-37 lb-ft (45-50 N·m).
Change 1
6-36.15/(6-36.16 Blank)