TM 9-2320-366-34-3
Change 2
16-441
c. Adjustment.
(1)
Install tee fitting (1) on 90-degree fitting (2).
(2)
Install snubber (3) on tee fitting (1).
(3)
Install transducer (4) on snubber (3).
(4)
Install cable (5) to transducer (4).
(5)
Position hose (6) on tee fitting (1).
(6)
Deleted.
(7)
Tighten hose (6) to 35-39 lb-ft (47-53 N•m).
(8)
Open hydraulic reservoir supply and return valves
(TM 9-2320-366-10-2).
(9)
Raise underlift approximately two feet (TM 9-2320-
366-10-2).
(10)
Verify STE/ICE-R reads 1950 psi (13445 Kpa).
(11) Loosen jam nut (8) on counterbalance valve (9).
(12)
Operate underlift (TM 9-2320-366-10-2).
(13)
Adjust screw (10) until STE/ICE-R reads 1950 psi
(1345 Kpa).
(14)
Hold adjustment screw (10) and tighten jam nut (8)
on counterbalance valve (9).
CAUTION
NOTE
Perform steps (11) through (14) if pressure
reading was not 1950 psi (13445 Kpa).
Steps (12) and (13) must be preformed at
the same time to get a correct reading.
Failure to comply may result in damage to
NOTE
Turn adjustment screw clockwise to increase
pressure and counterclock-wise to decrease
pressure.