TM 9-2320-386-24-1-1
0025 00
0025 00-17
ITEM
NO.
INTERVAL
ITEM TO
CHECK/
SERVICE
EQUIPMENT NOT
READY/AVAILABLE
IF:
PROCEDURE
Table 1. Unit Preventive Maintenance Checks and Services (Contd).
NOTE
Perform all semiannual and annual
checks listed in this table.
38
Biennially
Cooling
system
[RPL]
a.
Replace thermostat (WP 0077 00).
b.
Clean and flush radiator (WP 0068 00).
39
Biennially
Air com-
pressor
Remove discharge fittings and inspect
compressor discharge port and discharge
line for excessive carbon deposits. If there
are excessive carbon deposits, clean or
replace air compressor (WP 0169 00).
WARNING
Air system components are subject to
high pressure. Always relieve pressure
before loosening or removing air
system components. Failure to do so
may result in serious injury to
personnel.
Always wear eye protection when
draining air reservoirs. Failure to do so
may result in injury to personnel.