TM-9-2320-387-24-1

TRUCK, UTILITY: S250 SHELTER CARRIER, 4X4, M1113

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE, VOLUME 1

DECEMBER 1997
CHANGE 1

  TM-9-2320-387-24-1 - Page 859 of 1205

TM9-2320-387-24-l
4-76. SLAVE RECEPTACLE AND CABLE MAINTENANCE (Cont’d)
1
3.
4.
5.
6.
7.
8.
Instah battery negative cable (11) and slave negative cable (10) on shunt (1) with lo&washer (9) and
capscrew (8). Tighten capscrew (8) to 8 lb-R (11 Nom).
In&ah slave positive cable (3) through compression nut (22) and backshell (21) on receptacle (16)
with lockwasher (20) and capscrew (19).
Install slave negative cable (10) on receptacle (16) with lockwasher (14) and capscrew (13).
Apply silicone compound on receptacle (16) terminals, ah exposed metal on rear of receptacle (16),
and area under cover (18) on front of receptacle (16).
Install backshell (21) on receptacle (16).
Tighten compression nut (22) on backshell (21).
0
2
FOLLOW-ON TASK: Install battery tray (para. 4-75).
4-133