TM 9-2320-440-13&P
0032-2
0032
LHS DOES NOT OPERATE (CONTINUED)
THAAD0463B
NOTE
Each VIM has two HEART BEAT indicator lights.
One HEART BEAT indicator light will
steadily illuminate and the second HEART BEAT indicator light will flash when the VIM is
operating correctly.
Step 2.
Check if one HEART BEAT indicator light (green) is illuminated and the second HEART
BEAT indicator light (red) is flashing on both VIMs.
If the HEART BEAT indicators lights are not illuminated as indicated on both
VIMs, troubleshoot LHS Cab Control Fails Self Test or No VIM Heart Beat
Indication (WP 0030).
Step 3.
Start engine (
Check if ground rod driver operates (WP 0010).
If ground rod driver does not operate, troubleshoot LHS and MRP Do Not
Operate (WP 0029).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TM 9-2320-347-10)