TM 9-2320-440-13&P
0032-3
0032
LHS DOES NOT OPERATE (CONTINUED)
THAAD0464
NOTE
Perform Step 4 only if MRP rack locks are disengaged.
MRP present proximity switches must be active to engage MRP locks.
If MRP rack is not
loaded, activate both MRP present proximity switches by placing metal objects over
proximity switches while engaging MRP rack locks.
Step 4.
If MRP is not loaded, place metal objects over MRP present proximity switches.
Operate rack locks (WP 0012). Check if MRP rack locks engage.
If MRP rack locks do not engage, go to Step 17.
NOTE
MRP elevation cylinders must be in their fully stowed position to operate LHS and
disengage rack locks.
Step 5.
Check if left and right elevation cylinders are in their stowed position.
a.
If MRP rack is loaded, stow left and right elevation cylinders (WP 0007)
and go to Step 6 (WP 0032).
b.
If MRP rack is not loaded, stow left and right elevation cylinders using
bypass procedure (WP 0032) and go to Step 6.
NOTE
MRP rack locks are disengaged when RACK LOCKS ENGAGED indicator lights are not
illuminated or flashing.
Step 6.
Operated rack locks (WP 0012). Check if rack locks disengage.
If rack locks do not disengage, go to Step 9.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION