AIR RIDE SUSPENSION RIDE ROUGH OR UNSTABLE (CONTINUED)
THAAD0052
NOTE
Soap water may be used to locate air leaks.
Step 11.
Inspect control valve linkage on two air ride suspension ride height control valves for
damage and binding.
Repair or replace ride height control valve linkage (WP 0150) and perform
ride height adjustment (WP 0053).
Step 12.
Perform ride height control valve adjustment on both air ride suspension ride height
control valves (WP 0053). Then operate vehicle according to UNIT SOP and monitor
air suspension system for rough or unstable ride.
a.
If system provides a normal ride, problem is corrected.
b.
If system does not provide a normal ride, notify Supervisor.