TM 9-2320-440-13&P
0064-2
0064
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
.
4.
Remove two locknuts (11), washers (12), screws (13), gasket (14), and grounding bar (4) from generator
platform (15). Discard locknuts.
5.
Remove two screws (16) and washers (17) from grounding bar (4).
END OF TASK
INSTALLATION
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away
from open fire and use in well-ventilated area.
If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
1.
Apply sealing compound to threads of two screws (16) and install two washers (17) and screws (16) on
grounding bar (4).
NOTE
Epoxy primer and epoxy hardener must be applied to side of grounding bar that will be
mounted to generator platform.
2.
Following manufacturer’s guidelines, apply epoxy primer to grounding bar (4).
3.
Following manufacturer’s guidelines, apply epoxy hardener to grounding bar (4).
4.
Install gasket (14) on grounding bar (4).
5.
Install gasket (14) and grounding bar (4) on generator platform (15) with two screws (13), washers (12), and
locknuts (11).
THAAD0153