TM 9-2320-440-13&P
0079-2
0079
INSTALLATION/ADJUSTMENT
NOTE
•
Both MRP rack lock disengaged proximity switches are installed and adjusted the same
way. Right side shown.
1.
Install two nuts (3) on proximity switch (4).
2.
Install proximity switch (4) into MRP rack lock cylinder (5).
3.
Screw proximity switch (4) in fully until it contacts cylinder rod of MRP rack lock cylinder (5).
4.
Mark proximity switch (4) and then retract proximity switch (4) one complete turn and tighten two nuts (3).
5.
Connect connector (1) to connector (2).
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Connect batteries (TM 9-2320-325-14&P).
2.
Check MRP rack lock cylinder operation and verify proximity switch is working properly (WP 0011).
3.
Remove wheel chocks (
END OF TASK
END OF WORK PACKAGE
THAAD0026
TM 9-2320-347-1)0