8.
Install junction box cover (2) on junction box (3) and tighten four screws (1).
END OF TASK
ADJUSTMENT
1.
Adjust height between top of proximity switch (17) and top of target plate (24) to 0.38 in. ± 0.094 in.
(9.65 mm ± 0.25 mm) and tighten two locknuts (20).
2.
Using a feeler gage, adjust clearance between proximity switch (17) and target plate (24) to 0.125 in. ± 0.01
in. (3.175 mm ± 0.25 mm) and tighten two nuts (19).
3.
Tighten two screws (13).
END OF TASK