19. Apply sealing compound to threads of two screws (16).
20. Install two clamp halves (18) and mounting switch plate (15) on LHS main frame (19) with two
lockwashers (17) and screws (16).
21. Install proximity switch (14) on mounting switch plate (15) with two nuts (13).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
22. Install wires 1466 (8), 1474 (6), and 1435 (4) in junction box (3) with sealing ring (12), washer (11), and
collar (10).
23. Install wire 1466 (8) on terminal (9).
24. Install wire 1474 (6) on terminal (7).
25. Install wire 1435 (4) on terminal (5).