TM-9-2320-440-13-P

TERMINAL HIGH ALTITUDE AREA DEFENSE (THAAD) CARRIER

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

AUGUST 2010

  TM-9-2320-440-13-P - Page 638 of 1616

TM 9-2320-440-13&P
0076-6
0076
9.
Grind off paint in area marked in step (8) for sensor plate (20) to be mounted.
10. Mark hook arm (21) 2.59 in. (6.58 cm) from boss (26) on hook arm (21).
11. Aline sensor plate (20) 0.15 in. (3.8 mm) below top edge of hook arm (21).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
12. Position sensor plate (20) with two clamps on hook arm (21) as shown.
13. Mark line around sensor plate (20) from hook arm (21).
14. Remove two clamps and sensor plate (20) from hook arm (21).
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
NOTE
Mix epoxy according to directions on package.
Epoxy takes approximately 15 minutes to cure.
15. Mix epoxy and apply to sensor plate (20) and hook arm (21).
16. Clamp sensor plate (20) to hook arm (21) in marked position until cured.
17. Remove clamps from hook arm (21).
18. Prime and paint area as necessary (TM 43-0139).
THAAD0061