TM 9-2330-227-14&P
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5. ALL LIGHTS DO NOT WORK, LATE M146 - CONTINUED
Step 10.
Step 11.
Step 12.
Step 13.
Step 14.
Step 15.
Step 16.
Repeat step 8 for branch circuit breaker number 3.
Using multimeter set to read continuity, put red probe on one end
of wire leading from right main circuit breaker to number 3 breaker
in branch circuit breaker box and black probe on the other end.
If multimeter reads no continuity, notify Direct Support
Maintenance.
Using multimeter set to read continuity, put red probe on one end
of wire leading from number 3 circuit breaker to front
ON/OFF switch and black probe on the other end.
a.
b.
If multimeter reads no continuity, notify Direct Support Maintenance.
Remove front ON/OFF switch (page 4-35). Using multimeter
set to read continuity, put red probe in contact on side
with just one contact. Put black probe in one of the contacts
on other side. Check reading on multi meter. Flip switch,
and check the reading again.
Repeat step 13a, putting black probe in the other contact on
that side.
If multimeter reads no continuity with either step 13a or 13b,
replace switch (page 4-35).
Install front ON/OFF switch (page 4-35). Repeat steps 13a and 13b for
rear ON/OFF switch.
Install rear ON/OFF switch (page 4-35). Repeat steps 13a and 13b for
ON/OFF blackout switch.
Install ON/OFF blackout switch (page 4-35). Using multimeter set
to read continuity, put red probe on one end of wires leading from front
ON/OFF to back ON/OFF switch and black probe on the other.
If multimeter reads no continuity, notify Direct Support Maintenance.
4-23