4-142
page 2-13
page 2-23
TM 9-2330-227-14&P
RELAY VALVE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION - CONTINUED
15.
Relay valve(1)
Two adapters (2)
a. Wrap threads clockwise two
16.
Air line (3)
Nut (5)
and adapter (4)
17.
Air line (6)
Nut (8)
and elbow (7)
18.
Two air lines (9)
Two nuts
and adapters (2)
turns with teflon tape.
b. Screw in, and tighten using 9/16-inch
box-end wrench.
Screw in, and tighten using 7/8-inch
open-end box wrench and 11/16-inch
open-end wrench.
Screw in, and tighten using 5/8-inch
open-end box wrench and 1/2-inch open-
end wrench.
(10)
Screw in, and tighten using 5/8-inch
open-end box wrench and 9/16-inch open-
end wrench.