TM9-2330-328-14&P
ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Continued
0014 00
S – Semiannually
A – Annually
Item
ITEM TO BE INSPECTED
No.
Interval
Procedure:
5
Semiannual
SPRINGS AND U-BOLTS
a.
Inspect springs
(1)
for broken leaves. Report defective springs to Direct Support
Maintenance.
b.
Inspect U-bolts
(2)
for breakage and loose nuts. Tighten loose nuts to
285 lb.-ft. (386 N•m). Report broken U-bolts
(2)
to Direct Support Maintenance.
6
Semiannual
AXLES
Inspect axles
(1)
for cracks, damaged brackets
(2)
, and pads
(3)
report
deficiencies to Direct Support Maintenance.
0014 00-4
1
2
1
2
3