TM 9-2330-334-13&P
DRAWBAR DOES NOT RAISE/LOWER -Continued
0050 00
PNEUMATIC TROUBLESHOOTING - Continued
Table 1.
Drawbar Does Not Raise/Lower - Continued.
0050 00-7
Change 1
INDICATION/CONDITION
DECISION (NO/YES)
PROCEDURAL STEPS
6.
Does air hose 003 have any
kinks, holes, leaks?
No
Go to (Indication/Condition
7).
1.
Connect air hose 003 to port
A on drawbar lift control
valve.
Yes
Replace air hose 003.
2.
Lift turntable from frame for
access (WP 0099 00).
3.
Apply soapy water solution
to air hose 003, fittings, and
connector A on drawbar lift
control valve.
4.
Raise handle on drawbar lift
control valve.
5.
Check air hose 003 and
fittings between drawbar lift
control valve and pressure
relief valve for bubbles
indicating holes or leaks.